OTHER ENGINE TYPES
Jenbacher Type 2: J208
THE NEXT GENERATION JENBACHER TYPE 2F ENGINE
The reference for durability and reliability – now with higher efficiency!
Introduced in 1976, the Jenbacher Type 2 engine offers high efficiency with a durable and reliable design.
The stationary engine provides excellent durability, while enhanced components and proven control and monitoring give the Type 2 engine outstanding reliability.
More than 1,300 engines delivered since 1976.
J208 – efficient L8-cylinder power generation solution for small-/mid-scale businesses.
Change the scope of supply by clicking on a thumbnail.
Scope of supply:
* Provided technical data is for information only. Data ranges are calculated considering various gas quality levels and ambient conditions (standard or hot/tropical conditions, etc.).
Jenbacher can change the technical data unilaterally. In the case of such change, we will update the data on our pages as soon as we can.
Please reach out to our experts to get help with engines selection, obtain the technical parameters for your gas composition.
Output and efficiency at generator terminals. Energy input is according to DIN ISO 3046 and DIN 6271, respectively, with a tolerance of + 5%.
All data according to full load and subject to technical development and modification.
Based on emission values of 250 and 500 mg/Nm3 NOx at 5% O2 at dry exhaust gas.
Base for biogas and sewage gas versions: 65% CH4 / 35% CO2.
Base for landfill gas version: 55% CH4 / 40% CO2 / Rest N2.
L: 4,250 x W: 1,600 x H: 2,450 mm
L: 4,500 x W: 1,900 x H: 2,450 mm
L: 12,200 x W: 2,500 x H: 2,600 - 5000 mm
Highlights of Jenbacher Type 2F engines
Building on its proven heritage, the new Jenbacher Type 2F 50 Hz engine now leads the way with next-generation technology innovation that delivers up to a 3 percentage point efficiency boost compared to the earlier engine versions and now up to 360 kWel output without sacrificing its proven reliability or robustness.
In addition to delivering efficiency as high as 41.8% when operating on pipeline gas, the Type 2F engine is optimized for reduced total hydrocarbon (THC) emissions, future-proof fuel flexibility, and enhanced serviceability.
Moreover, the latest 2F technology is retrofittable for most of the installed Jenbacher Type 2 fleet.
To use Youtube, please give your consent to the creation of cookies used by this service.

Innovative design features
New cylinder head (4V)
The new cylinder head has been optimized for better charge exchange and improved cooling. It also offers reduced THC emissions, optimized combustion, and more robust material pairings for valves and valve seats.

New power unit
The new connecting rod of the 2F series enables the use of the established piston from the 3F series. This contributes to the lower clearance and thus enables lower THC emissions, better combustion, and lower oil consumption. Other important aspects of the design include a new piston bowl shape and new cylinder liners and scraper rings.
New intercooler
The new intercooler offers 40% more power with an intercooler water temperature (ICWT) of 70° C and, therefore, use of the entire mixture’s heat. This not only leads to higher overall efficiency but also to simple installation and a reduction in auxiliary power for the low-temperature circuit.
New valve train (4V)
A new valve train with a floating bridge makes service easier.

New camshaft
The new Miller camshaft enables greater efficiency of the charge exchange and thus contributes to improved engine efficiency. It also reduces THC emissions.

New ignition box
This latest-generation ignition system, also adopted from the 3F series, enables efficient combustion.
Scope of supply:
The genset scope of supply is designed for applications that require power generation only. If you are looking for simultaneous power and heat generation, please consider the Combined Heat and Power Module (CHP Module) scope of supply.
Minimum scope of supply for the genset:
- Engine and alternator installed on the frame
- Control panel
- Gas train
The scope of supply can be extended further with various balance of plant (BOP) options. Reach out to our specialists for help in selecting scope of supply and BOP options to fulfill your project’s needs.
Gensets can be installed inside a building or container. For more details about our containerized solutions, click here.
The Combined Heat and Power Module (CHP Module) allows you to generate power and heat simultaneously at very high total efficiencies, reaching 90% and even more.
Typical scope of supply:
- Engine and alternator installed on the frame
- Control panel, gas train
- Heat exchangers, including exhaust gas heat exchanger
CHP Modules can generate hot water or steam at various parameters and can be integrated with your existing heat infrastructure. You can select the option that fits your project’s needs among the various heat recovery schemes provided by INNIO Group.
The scope of supply can be extended further with various balance of plant (BOP) options. Reach out to our specialists for help in selecting scope of supply and BOP options to fulfill your project’s needs.
CHP Modules can be installed inside a building or container. To see more details about INNIO Group’s Jenbacher containerized solutions, click here.
INNIO Group’s Jenbacher containerized solutions are “ready-to-use” power plants that allow for quicker commissioning. Jenbacher containerized power plant solutions have been produced for decades, providing advanced power generation technologies wrapped in well-designed, reliable packages.
Both genset and CHP Module solutions can be supplied as containerized versions, depending on your needs.
Typical scope of supply:
- Engine and alternator installed on the frame
- Control panel, gas train
- Container with integrated ventilation system
- Cooling systems
- Lube oil supply system
- Exhaust gas heat exchanger (for CHP module)
The scope of supply can be extended further with various balance of plant (BOP) options. Reach out to our specialists for help in selecting scope of supply and BOP options to fulfill your project’s needs.
Balance of Plant (BOP)
The right auxiliary equipment is of critical importance in ensuring that a power solution is economically feasible and provides your business with reliability, availability, and efficiency. Click on the provided BOP options to learn more.
Reach out to our experts to select the configuration that fits your business’ needs.
Available BOP elements may vary, depending on the engine and application type.
Higher efficiency
Improved fuel efficiency by up to 3 percentage points
Higher output
Output of up to 360 kWel without compromising on proven reliability and robustness
Reduced THC emissions
For a smaller ecological footprint
Lower oil life-cycle costs
Lower oil consumption and longer service life of the lubricating oil
Convenient upgrade
Upgrade installed engines to the latest technology at any time - ideally during a minor or major overhaul.
Future-proof fuel flexibility
The future-proofed F-generation Type 2 fuels include renewable energy sources such as biogas and energy sources such as propane or special gases. It is also possible to equip the engine with a "Ready for Hydrogen" option.
Watch the video on the new Jenbacher 208 F engine:
To use Youtube, please give your consent to the creation of cookies used by this service.

Customer-only Resources
Get access to almost 2,000 Resources (such as Drawings, Service Technician Instructions, User Manuals, & more…) for Jenbacher Gas Engines with our dedicated Portal which includes advanced (yet easy to use!) search capabilities to find what you’re looking for.
Subscribe to our monthly Services Newsletter and additional materials to stay up-to-date with the latest Jenbacher technical news.
Type 2 Case studies

Permoda Plants (COL)
With heat and power for the textile industry that meets stringent local emissions requirements at high altitudes
Location
Installed engines
Electrical output
Thermal output
Total efficiency
Energy source
Commissioned

El Gabar Al Asfar Wastewater Treatment Plant (EGY)
boosts power and cuts costs at one of Egypt’s largest wastewater treatment facilities
Location
Installed engines
Electrical output
Thermal output
Total efficiency
Energy source
Commissioned

Bad Reichenhall (GER)
Location
Installed engines
Electrical output
Thermal output
Energy source
Commissioned

Hyosung (KOR)
with Asia Pacific’s first 100% hydrogen engine power plant
Location
Installed engines
Electrical output
Thermal output
Energy source
Commissioned

The Jenbacher emissions reduction package for full control over your exhaust gas levels
Manuel Kirfel, Development/Sales Heat, STAWAG - Stadt- und Städteregionswerke Aachen AG

STAWAG (GER)
for full control over your exhaust gas levels
Location
Installed engines
Electrical output
Thermal output
Energy source
Commissioned







Permoda Plants (COL)
With heat and power for the textile industry that meets stringent local emissions requirements at high altitudes
Location
Installed engines
Electrical output
Thermal output
Total efficiency
Energy source
Commissioned

El Gabar Al Asfar Wastewater Treatment Plant (EGY)
boosts power and cuts costs at one of Egypt’s largest wastewater treatment facilities
Location
Installed engines
Electrical output
Thermal output
Total efficiency
Energy source
Commissioned

Bad Reichenhall (GER)
Location
Installed engines
Electrical output
Thermal output
Energy source
Commissioned

Hyosung (KOR)
with Asia Pacific’s first 100% hydrogen engine power plant
Location
Installed engines
Electrical output
Thermal output
Energy source
Commissioned

The Jenbacher emissions reduction package for full control over your exhaust gas levels
Manuel Kirfel, Development/Sales Heat, STAWAG - Stadt- und Städteregionswerke Aachen AG

STAWAG (GER)
for full control over your exhaust gas levels
Location
Installed engines
Electrical output
Thermal output
Energy source
Commissioned
Our Services
Jenbacher Services
Bringing proven outcomes across the life cycle of your gas engines means less unplanned downtime, greater workforce efficiency, and lower operating costs. From commissioning to overhauling, our global network of qualified service experts provides the support you need, when you need it, by providing the latest technology.
Consult an expert
Send us a message and we’ll contact you to start the conversation.
Whether your business is looking for onsite power solutions, access to electricity, decreased energy costs, or even to sell electricity back to your local grid/consumers, Jenbacher regional experts can advise you on which solution makes the most sense for you.